User Tools

Site Tools


electrical

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
electrical [2026/07/06 00:35] jmctelectrical [2026/07/06 21:30] (current) jmct
Line 31: Line 31:
 It is common to see one of the output controllers doing a lot more work that the other. Here's an example from a particularly sunny day: It is common to see one of the output controllers doing a lot more work that the other. Here's an example from a particularly sunny day:
  
-{{ :charge-controller-side-by-side.jpeg?400 |}}+{{ :charge-controller-side-by-side.jpeg?600 |}}
  
 While their input is relatively similar (66.3V vs. 63.7V, respectively), their _output_ is very different: 0 Watts/0.3kWh vs. 401 Watts/6.9kWh, respectively (it's a happy coincidence that the lower input controller is actually providing more output because the input, as long as it is above the 27V threshold, is irrelevant for the differing output. While their input is relatively similar (66.3V vs. 63.7V, respectively), their _output_ is very different: 0 Watts/0.3kWh vs. 401 Watts/6.9kWh, respectively (it's a happy coincidence that the lower input controller is actually providing more output because the input, as long as it is above the 27V threshold, is irrelevant for the differing output.
Line 41: Line 41:
 ==== Sanity Test ==== ==== Sanity Test ====
  
-In the morning when there is sun but the batteries have been drained over night, we should see both controllers outputting a lot.+In the morning when there is sun but the batteries have been drained over night, we should see both controllers providing outputThe following is a photo from a morning charge on an overcast day:
  
-<todo>Check that both controllers have output during a bulk-charging time</todo>+{{ :wiki:midnite-controller-charging.jpeg?600 |}}
  
  
Line 60: Line 60:
  
 The MidNite controllers and the battery bank are connect to a {{ :dcdisconnectuserguide-42813.pdf | Trace Engineering DC Disconnect}}. The MidNite controllers and the battery bank are connect to a {{ :dcdisconnectuserguide-42813.pdf | Trace Engineering DC Disconnect}}.
 +
 +
 +====== Battery Health Checking ======
 +
 +[[batterylist|batterylist]]
 +
electrical.1783298155.txt.gz · Last modified: by jmct